Specification details for Celsius weathering grade

EN-Construction-Product-Tubes-Celsius-Dimensional tolerancesTSUK

Dimensional tolerances

Dimensional tolerances EN10210: Part 2

Celsius tubes are manufactured to the tolerances defined in EN 10210: Part 2. Tighter tolerances are available on request and if you require specific tolerances in excess of this, please contact us.

  Circular/Ellipticals Square/Rectangular
Outside dimension
(D B and H)
Circular ±1% with a min of ±0.5mm
and maximum of ±10mm
Ellipticals ±1% with a min of ±0.5mm
(The permitted tolerance is
twice the value for H<250)
±1% with a min of ±0.5mm
Thickness (T) -10%
Note: Positive deviation limited
by mass tolerance
-10%
Note: Positive deviation limited
by mass tolerance
Squareness of side - 90 degrees ±1 degree
External corner profile - 2T max at each corner*
(EN10210 has 3T max)
Concavity/convexity (x) - – ±1% of the side, measured
independently of the tolerance
on the outside dimension
Twist (V) Ellipticals: 2mm plus 0.5mm/m max
(The permitted tolerance is
twice the value for H<250)
2mm plus 0.5mm/m max
Section is placed on a flat surface
with one end held flat. At the other
end the height difference of 
the two lower corners is taken
Mass (M) ±6% on individual lengths ±6% on individual lengths
Straightness Maximum 0.2% of the total length and 
3mm over every 1m length
Ellipticals: The permitted tolerance is
twice the value for H<250
Maximum 0.2% of total length
and 3mm over every 1m length
Length +150mm/-0mm +150mm/-0mm
Out-of-roundness (O) Circular 2% for hollow sections having
a diameter to thickness ratio not exceeding 100
-

* Unless shown otherwise

EN-Construction-Book a CPD

Book a CPD

We offer a range of face to face and online CPDs aimed at Engineers and Architects

These free seminars can be booked at any time between 9am and 5pm. Our online webinars can all be delivered via Skype for Business and Teams, but we can consider other platforms if this will not work for your practice.

Below outline the CPDs we have available - Book yours today

  • Decarbonising your structural hollow section designs
  • Essentials of Structural Hollow Sections
  • Welded Joints in Tubular Steelwork - Eurocode 3 Part 1-8
  • Concrete Filled Hollow Sections - Composite Design – Eurocode 4
  • Composite Floor Deck in Construction
  • Structural Roof Deck in Construction
  • Specifying metal clad envelope systems in accordance with ADB2 of the building regulations and the value of large scale system testing
  • RIBA 2030 climate challenge: How steel building envelope solutions contribute
  • Pre-finished steel standing seam systems for roof & wall cladding
  • CDM regulations 2015 and their impact on steel building envelope specification.
  • Steel building envelope systems for non-domestic buildings
  • Steel for roof and wall cladding

Book your CPD today

RIBA Approved CPD tata steel
CPD Tata Steel