EN-Construction-Product-Tubes-Celsius-Dimensional tolerancesTSUK
Dimensional tolerances EN10210: Part 2
Celsius tubes are manufactured to the tolerances defined in EN 10210: Part 2. Tighter tolerances are available on request and if you require specific tolerances in excess of this, please contact us.
Circular/Ellipticals | Square/Rectangular | |
---|---|---|
Outside dimension (D B and H) |
Circular ±1% with a min of ±0.5mm and maximum of ±10mm Ellipticals ±1% with a min of ±0.5mm (The permitted tolerance is twice the value for H<250) |
±1% with a min of ±0.5mm |
Thickness (T) | -10% Note: Positive deviation limited by mass tolerance |
-10% Note: Positive deviation limited by mass tolerance |
Squareness of side | - | 90 degrees ±1 degree |
External corner profile | - | 2T max at each corner* (EN10210 has 3T max) |
Concavity/convexity (x) | - | – ±1% of the side, measured independently of the tolerance on the outside dimension |
Twist (V) | Ellipticals: 2mm plus 0.5mm/m max (The permitted tolerance is twice the value for H<250) |
2mm plus 0.5mm/m max Section is placed on a flat surface with one end held flat. At the other end the height difference of the two lower corners is taken |
Mass (M) | ±6% on individual lengths | ±6% on individual lengths |
Straightness | Maximum 0.2% of the total length and 3mm over every 1m length Ellipticals: The permitted tolerance is twice the value for H<250 |
Maximum 0.2% of total length and 3mm over every 1m length |
Length | +150mm/-0mm | +150mm/-0mm |
Out-of-roundness (O) | Circular 2% for hollow sections having a diameter to thickness ratio not exceeding 100 |
- |
* Unless shown otherwise
EN-Construction-Product-Celsius hot finished hollow sections-downloads - Weathering grade
Download:
EN-Construction-Brochure-Celsius Overview Brochure
Celsius overview brochure
EN-Construction-Design_guide-Design of Structural Hollow Sections Welded Joints
Design of structural hollow sections welded joints
EN-ConstructionEngineering-Download-EPD-Tata Steel Structural hollow sections
Tata Steel EPD structural hollow sections
EN-Construction-Book a CPD
We offer a range of face to face and online CPDs aimed at Engineers and Architects
These free seminars can be booked at any time between 9am and 5pm. Our online webinars can all be delivered via Skype for Business and Teams, but we can consider other platforms if this will not work for your practice.
Below outline the CPDs we have available - Book yours today
- Decarbonising your structural hollow section designs
- Essentials of Structural Hollow Sections
- Welded Joints in Tubular Steelwork - Eurocode 3 Part 1-8
- Concrete Filled Hollow Sections - Composite Design – Eurocode 4
- Composite Floor Deck in Construction
- Structural Roof Deck in Construction
- Specifying metal clad envelope systems in accordance with ADB2 of the building regulations and the value of large scale system testing
- RIBA 2030 climate challenge: How steel building envelope solutions contribute
- Pre-finished steel standing seam systems for roof & wall cladding
- CDM regulations 2015 and their impact on steel building envelope specification.
- Steel building envelope systems for non-domestic buildings
- Steel for roof and wall cladding